Mechanical Ventilation Heat Recovery (MVHR)

MVHR systems provide a continuous supply of filtered fresh air to a building while extracting stale, moist air from rooms such as kitchens and bathrooms. As the two airflows pass through a heat exchanger, heat from the outgoing air is transferred to the incoming air, so less of the warmth already in the building is lost through ventilation.

We design, supply, install, balance and commission MVHR systems for domestic and commercial properties, and provide ongoing maintenance and diagnostic surveys for existing systems. Potential benefits of a correctly designed and commissioned MVHR system include:

  • A continuous supply of filtered fresh air
  • Controlled removal of moisture, odours and stale air
  • Recovery of heat from extracted air, reducing ventilation heat loss
  • Ventilation without needing to open windows

Actual performance depends on the building, system design, installation quality and ongoing maintenance. We can advise on whether MVHR is suitable for your property.

FAQ's

MVHR is a balanced, whole-building ventilation system. A central unit continuously extracts air from wet rooms such as kitchens, bathrooms and utility rooms, and supplies filtered outdoor air to habitable rooms such as bedrooms, living rooms and offices. A heat exchanger inside the unit transfers heat from the extracted air to the incoming supply air, reducing the heat lost through ventilation.

The unit contains two fans and a heat exchanger. One fan draws stale air from the extract points and discharges it outside; the other draws in outdoor air, passes it through filters and delivers it to the supply points. Both airstreams pass through the heat exchanger, normally without mixing, so the incoming air is tempered by the outgoing air. Supply and extract airflow rates are set during commissioning so that the system runs in balance.

System selection starts with the building rather than the product. We look at the property type and layout, airtightness, occupancy, the number and location of wet rooms, available space for the unit and ductwork, and whether the project is a new build, extension or refurbishment.

Depending on these factors, MVHR may be the most suitable option, or another approach such as mechanical extract ventilation (MEV) or intermittent extract fans may suit the building better. We explain the options and the reasons behind our recommendation before any design work begins.

Design airflow rates are calculated for each room based on the building’s size, number of bedrooms, room use and the relevant requirements of Approved Document F. These figures set the continuous and boost rates for each supply and extract terminal.

We then calculate the pressure losses through the ductwork, fittings, filters, heat exchanger and terminals. The unit is selected so that it can deliver the design airflow rates against that system pressure, rather than being sized on headline capacity alone.

Ductwork design has a major effect on how well an MVHR system performs. Our designs cover duct routes, sizes and materials, and aim to:

  • Keep air velocities at levels suited to quiet operation.
  • Limit bends, restrictions and long runs that add pressure loss.
  • Insulate ducts where they pass through cold spaces, and insulate the intake and exhaust ducts to reduce the risk of condensation.
  • Position the intake and exhaust terminals to avoid stale air being drawn back in.
  • Allow access for inspection, cleaning and future maintenance.

Noise is considered at design stage rather than after installation. The main factors are unit selection and location, duct velocities, the use of attenuators (silencers) on the supply and extract runs, anti-vibration mounting, and the risk of sound passing between rooms through shared ductwork (cross-talk).

Correct balancing also matters: a system forced to run at a higher fan speed than designed to make up for restrictions will usually be louder. Where an existing system is noisy, a diagnostic survey can help identify the cause.

When the system is properly designed, installed and commissioned, MVHR can provide:

  • Continuous, controlled ventilation throughout the building.
  • Removal of moisture, odours and indoor pollutants at source.
  • Filtered supply air, with filter grades chosen to suit the location.
  • Reduced ventilation heat loss compared with ventilation that does not recover heat.
  • Ventilation that does not rely on opening windows.

Results in practice depend on the building, the design, the quality of installation and how the system is maintained.

Yes. MVHR is used in houses, flats, offices and a range of other commercial premises. The design approach is the same, but commercial systems often involve larger units, longer duct runs, zoning and integration with other building services. We design and install systems for both domestic and commercial projects.

No. MVHR is a ventilation system. Recovering heat from the extract air reduces the heat lost through ventilation, but the building still needs its own heating, and cooling where required. Some units include a summer bypass, which allows outdoor air to bypass the heat exchanger when heat recovery is not wanted.

Once installation is complete, we measure the airflow at each supply and extract terminal using calibrated instruments and adjust the system until the measured rates align with the design values for both continuous and boost settings.

We record the results, check that controls, boost functions and any summer bypass operate correctly, and complete the commissioning documentation required for Building Regulations notification.

At handover we provide:

  • Commissioning records showing the design and measured airflow rates.
  • The documentation needed for Building Regulations sign-off.
  • Manufacturer information for the unit and controls.
  • Guidance on using the controls, boost and bypass functions.
  • A recommended filter change and maintenance schedule.

We also walk through the system with the client or building manager so they know how it should be used and looked after.

Routine maintenance keeps the system running as it was commissioned. A typical service includes:

  • Cleaning or replacing filters in line with the manufacturer’s guidance.
  • Inspecting and cleaning the heat exchanger, fans and condensate drain.
  • Checking ductwork, terminals and the intake and exhaust grilles.
  • Measuring airflow rates and comparing them with the commissioning records.

We offer planned maintenance for domestic and commercial MVHR systems, including systems we did not originally install.

There is no fixed lifespan. It depends on the quality of the unit, the installation, the operating environment and how consistently the system is maintained. Filters are consumable items, and parts such as fans or control components may need replacing over the life of the system. Regular servicing allows wear to be picked up early.

Controls vary by manufacturer and model. Common options include boost switches in wet rooms, humidity or air-quality sensors, timed schedules and summer bypass. Some units also offer app control or remote monitoring. We confirm the control strategy at design stage so it suits how the building will be used.

We do not recommend it. Performance depends on correct airflow calculations, unit selection, duct design, installation and commissioning, and commissioning records are typically needed for Building Regulations sign-off. Our mechanical engineer-led team manages the full process, from survey and design through to installation, balancing, commissioning, handover and ongoing maintenance.

Eco Plus Systems Ltd has been certified with PAS 2030 (EEM) by NAPIT & Trustmark
government-recognised bodies

PAS 2030 is the industry specification for which all energy efficiency installers must be certified and compliant when carrying out energy efficiency measures under government initiatives such as ECO
NAPIT is one of the leading Government-authorised and United Kingdom Accreditation Service (UKAS) accredited membership scheme operators in the building services and fabric sector. There are currently more than 10,000 NAPIT registered installers in the electrical, heating, plumbing, ventilation & air-conditioning, microgeneration and building fabric trades across the UK domestic, commercial and industrial markets
It is an accreditation that reassures and protects homeowners that the firm they employ to work in their home complies with Trustmark government-endorsed quality for workmanship, understands fair trading practices and has consumer protection as an integral part of their business.